Beta Fulltext view is in preview — article structure may vary. Browse all articles
Contents
Open Access Journal of Ophthalmology Research Article 2 min read

Jackson Cross Cylinder

Partha Haradhan Chowdhury* and Brinda Haren Shah*
* Corresponding author
ISSN: 2578-465X  10.23880/oajo-16000S2-023  Received: October 06, 2018  Published: November 08, 2018
  views
 3 references
 1 figure
PDF
Keywords
Jackson Cross Cylinder JND technique
Abstract

This paper describes about Jackson Cross Cylinder, its technique and JND technique.

Partha Haradhan Chowdhury1* and Brinda Haren Shah2

Jankalyan Samiti Netra Prasikshan Sansthan, Pauri, Affiliated to Uttarakhand State Medical Faculty, Dehradun, India Samiti Netra Prasikshan Sansthan, Pauri, Affiliated to Uttarakhand State Medical Faculty, Dehradun, India Faculty, Dehradun, India, Email: optometrypublish@gmail.com This paper describes about Jackson Cross Cylinder, its technique and JND technique.

Keywords: Jackson Cross Cylinder; JND technique

Introduction

Jackson cross cylinder is an instrument by which we can be able to know:  Axis Refinement  Power of the cylindrical correction  Used for near point testing The procedure of Jackson Cross Cylinder should be followed without fogging. It is a sphero cylinder lens in which plus cylinder is incorporated at the front surface and it is indicated with green sign. Minus cylinder is incorporated at the posterior surface and it is indicated with the red sign [1, 2, 3]. So, according to the JCC power, we should know: A. If, JCC : +/- 0.25 i. +0.25/-0.50 ii. -0.25/+0.50 B. If, JCC: +/- 0.50 i. 0.50/-1.00 ii. -0.50/+1.00 C. If, JCC : +/- 0.75 i. +0.75/-1.50 ii. -0.75/+1.50 D. If, JCC: +/-1.00 i. +1.00/-2.00 ii. -1.00/+2.00 E. If, JCC : +/-1.25 i. +1.25/-2.50 ii. -1.25/+2.50

Technique

By the JCC, we can do axis refinement and power of the cylinder.

I. Axis Refinement

Here, JCC handle is parallel with the correcting lens axis. Eg, RE: -0.50Dcyl *180 LE: -0.50 Dcyl*180 During, Axis Refinement, JCC handle will be placed parallel to the axis of the correcting lens. It means, in this time automatically, JCC axis will be positioned 45 degree and 135 degree compared to the correcting lens axis.

Figure 1: Axis Refinement II. Power of the Cylinder Correction
Click to enlarge
Figure 1: Axis Refinement II. Power of the Cylinder Correction

JCC axis is parallel with the axis of the correcting lens.1st time minus axis is parallel and then flip the JCC, plus axis will be parallel.

Just Noticeable Difference

By this technique, we can be able to know which JCC should be used according to high refractive error. JND technique with e.g. Eg. 1 If patient’s visual acuity is 20/200 In this technique, always 10 is divided by 100, i.e. 10/100 After that, if 200 is divided by 100 So, 200/100 = +/- 2.00 D In this case, +/- 2.00 D JCC is used. Eg. 2 If visual acuity of patient is 20/400, At first, 10 is divided by 100 So, 10/100 After that, 400 will be divided by 100 So, 400/100 = +/- 4.00 D In this case, +/- 4.00 D JCC will be used as per the case.

References

  1. William J Benjamin (2006) Borish's Clinical Refraction. 2nd (Edn.).
  2. Theodore Grosvenor, Theodore P. Grosvenor (2007) Primary Care Optometry, 5th (Edn.).
  3. Duke-Elder S, David Abrams (1978) Duke-Elder's Practice of refraction.
More from this journal

Cite this article

BibTeX
APA
RIS
@article{partha2018,
  title   = {Jackson Cross Cylinder},
  author  = {Partha Haradhan Chowdhury* and Brinda Haren Shah},
  journal = {Open Access Journal of Ophthalmology},
  year    = {2018},
  volume  = {3},
  number  = {Special Issue 2},
  doi     = {10.23880/oajo-16000S2-023}
}
Partha Haradhan Chowdhury* and Brinda Haren Shah (2018). Jackson Cross Cylinder. Open Access Journal of Ophthalmology, 3(Special Issue 2). https://doi.org/10.23880/oajo-16000S2-023
TY  - JOUR
TI  - Jackson Cross Cylinder
AU  - Partha Haradhan Chowdhury* and Brinda Haren Shah
JO  - Open Access Journal of Ophthalmology
PY  - 2018
VL  - 3
IS  - Special Issue 2
DO  - 10.23880/oajo-16000S2-023
ER  -