ISSN: 2573-1734
Authors: Sweta Sinha* and Kavita Goyal
Forensic identification of Transformer Oils seized under suspicious circumstances by Delhi Police have been examined and reported after analysis of samples in Digital Abbe’s Refractometer, Fourier Transform Infrared Spectrophotometer and Gas Chromatograph for identification and matching of seized materials with standard/original Transformer Oil to determine the source of pilferation. These rapid analytical tools provide authentic methods for forensic laboratories having constraint of time, samples and equipment at their disposal.
Keywords: Forensic; Transformer Oils; Abbe’s Refractometer; Fourier Transform Infrared Spectrophotometer; Gas Chromatograph; Pilferation