International Journal of Nuclear Medicine & Radioactive Substances (IJNMRS)

ISSN: 2689-8020

Review Article

Dosimetric Comparison: Volumetric Modulated Arc Therapy (VMAT) and 3d Conformal Radiotherapy (3d-CRT) in High Grade Glioma Cancer Experience of Casablanca Cancer Center at the Cheikh Khalifa International University Hospital

Authors: Benali I*, Elgouach H and Kaanouch O

DOI: 10.23880/ijnmrs-16000139

Abstract

Background: Intensity Modulated Radiation Therapy (IMRT) is currently employed as a major arm of treatment in multiforme glioblastoma (GBM). The present study aimed to compare 3D-CRT with IMRT to assess tumor volume coverage and OAR sparing for treatment of malignant gliomas. Materials and Methods: We assessed 22 anonymized patients datasets with High Grade Glioblastoma who had undergone post-operative Intensity Modulated Radiotherapy (IMRT) and 3D Conformal Radiotherapy (3D-CRT), This study will compare and contrast treatment plans Rapidarc and 3D-CRT to determine which technique improves significantly dosimetric parameters. Results: Plans will be assessed by reviewing the coverage of the PTV using mean, maximum and minimum doses while the OAR doses will be compared using the maximal doses for each, as set out in the QUANTEC dose limits. Conclusion: The use of IMRT seems a superior technique as compared to 3D-CRT for the treatment of malignant gliomas having the potential to increase dose to the PTV while sparing OARs optimally.

Keywords: HGG; IMRT; 3D-CRT; Dosimetric study

View PDF

F1 europub scilit.net